1.Features and Applications
The HCP8000 series current probes are wide band width DC/AC active current probes, featuring high bandwidth, fast and accurate capture the current wave, accuracy up to 1% and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.
Large Pliers
Model | HCP8150(A) | HCP8300(A) | HCP8500 | ||||
Bandwidth (-3dB) | HCP8150 | DC-12 MHz (Figure 10.a) | HCP8300 | DC- 6 MHz (Figure 13.a) | DC-5MHz (Figure 16) | ||
HCP8150A | DC-22 MHz (Figure 10.b) | HCP8300A | DC-8 MHz (Figure 13.b) | ||||
Rise time | HCP8150 | ≤29ns | HCP8300 | ≤58ns | ≤70ns | ||
HCP8150A | ≤16ns | HCP8300A | ≤50ns | ||||
Continuous maximum input range | HCP8150 | 150Arms (Figure 11.a) | HCP8300 | 300Arms (Figure 14.a) | 500Arms(Figure 17) | ||
HCP8150A | 150Arms (Figure 11.b) | HCP8300A | 300Arms (Figure 14.b) | ||||
Max peak current value | 300Apk | 500Apk | 750Apk | ||||
Range | 30A | 10X | 50A | 10X | 75A | 10X | |
150A | 100X | 300A | 100X | 500A | 100X | ||
Overload | 30A | ≥30APk | 50A | ≥50APk | 75A | ≥75APk | |
150A | ≥300APk | 300A | ≥500APk | 500A | ≥750APk | ||
Current transfer ratio | 30A | 0.1V/A | 50A | 0.1V/A | 75A | 0.1V/A | |
150A | 0.01V/A | 300A | 0.01V/A | 500A | 0.01V/A | ||
measurable current | 30A | 10mA | 50A | 10mA | 75A | 10mA | |
150A | 100mA | 300A | 100mA | 500A | 100mA | ||
Amplitude accuracy (DC,45-66Hz ) | 30A | ±1%±10mA | 50A | ±1%±10mA | 75A | ±1%±10mA | |
150A | ±1%±100mA | 300A | ±1%±100mA | 500A | ±1%±100mA | ||
Input impedance | HCP8150 | Referenc (Figure 12.a) | HCP8300 | Reference(Figure 15.a) | Reference (Figure 18) | ||
HCP8150A | Referenc (Figure 12.b) | HCP8300A | Reference(Figure 15.b) | ||||
Delay time | Probe | HCP8150 | 36ns | 41ns | 42ns | ||
HCP8150A | 30ns | ||||||
BNC (1m) | 5ns | ||||||
Terminal load | ≥100kΩ | ||||||
Power supply | DC 12V/1A(Standard Adaptor) | ||||||
Voltage of insulated wire | 600V CATII 300V CATIII | ||||||
Safety compliance | EN61010-1: 2010+A1:2019 EN 61010-2-032:2019 | ||||||
EMC standard | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |