深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
HCP8030(30A/DC~ 50 MHz)
HCP8030(30A/DC~ 50 MHz)

Bandwidth(-3dBDC-50MHz 

Rise time  ≤7ns





浏览次数:0
说明书: 产品说明书

1.Features and Applications

The HCP8000 series current probes are wide band width DC/AC active current probes, featuring high bandwidth, fast and accurate capture the current wave, accuracy up to 1% and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.




Small Pliers

Model

HCP8030(C/D/H)

HCP8050

HCP8070

Bandwidth

(-3dB)

HCP8030

DC-50MHz(Figure1.a)

DC-50MHz

(Figure4)

DC-30MHz

(Figure7)

HCP8030C

DC-70MHz(Figure1.b)

HCP8030D

DC-100MHz(Figure1.c)

HCP8030H

DC-120MHz(Figure1.d)

Rise time

HCP8030

7ns

7ns

11.6ns

HCP8030C

5ns

HCP8030D

3.5ns

HCP8030H

2.92ns

Continuous

maximum input

range

HCP8030

30ArmsFigure2.a

50Arms

(Figure5)

70Arms

(Figure8)

HCP8030C

30ArmsFigure2.b

HCP8030D

30ArmsFigure2.c

HCP8030H

30ArmsFigure2.d

Max peak current value

50Apk

75Apk

100Apk

Range

5A

1X

7.5A

1X

10A

2X

30A

10X

50A

10X

70A

20X

Overload

5A

5APk

7.5A

7.5APk

10A

10APk

30A

50APk

50A

75APk

70A

100APk

Current transfer ratio

5A

1V/A

7.5A

1V/A

10A

0.5V/A

30A

0.1V/A

50A

0.1V/A

70A

0.05V/A

measurable

current

5A

1mA

7.5A

1mA

10A

2mA

30A

10mA

50A

10mA

70A

20mA

Amplitude

accuracy (DC,45-66Hz )

5A

±1%±1mA

7.5A

±1%±1mA

10A

±1%±2mA

30A

±1%±10mA

50A

±1%±10mA

70A

±1%±20mA

Input

impedance

HCP8030

Reference Figure3.a

Reference (Figure6)

Reference (Figure9)

HCP8030C

Reference Figure3.b

HCP8030D

Reference Figure3.c

HCP8030H

Reference Figure3.d

Delay

time

Probe

14ns

14ns

23ns

BNC

(1m)

5ns

Terminal load

≥100kΩ

Power supply

DC 12V/1AStandard Adaptor

Voltage of insulated wire

300V CAT I

Safety compliance

EN61010-1: 2010+A1:2019  EN 61010-2-032:2019

EMC standard

EN61326-1:2013  EN61000-3-2:2014  EN61000-3-3:2013