Frequency range 30 MHz~1000MHz
Insertion loss(dB) 13 dB to 22 dB
Maximum allowable disturbance power <10 W
1. Summary
EM5018 Absorbing Clamp is mainly used for measuring the power interference signal from the power cable of EUT, frequency ranging from 30MHz to 1000MHz. EM5018 is in accordance with CISPR 16-1-3 regulation, with operating current over 25A, pore diameter around 20mm, can be widely used in the measurement of testing the interference signal of the standard power supply cable like CISPR 13/EN 55013, CISPR 14-1/EN 55014-1.
Electronics Specification
Frequency range | 30 MHz~1000MHz | |
Input loss | 13 dB to 22 dB | |
Clamp factor | -4 dB to +5 dB refer to the diagram below | |
Maximum allowable disturbance power | <10 W | |
Maximum allowable cable diameter | 20 mm | |
Clamp with gasket | 6mm | |
Maximum allowable DC or AC peak working current | 25 A | |
RF Output port | BNC, 50 Ω | |
Operating temperature | +4°C to +40°C | |
Dimension(W×H×D)mm | around 648*105*85mm | |
Weight | around 6.5kg |