深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
Low Frequency Flexible Current Probe CP9000LF Series
Low Frequency Flexible Current Probe CP9000LF Series

Typical accuracy ±1%

Max output voltage ±6Vpk

浏览次数:555
说明书: 产品说明书

1. Summary

CP9000LF series flexible current probe applies low frequency flexible probe with double ranges design, and was able to realize wide measurable current range, from 60A to 60kA. Guaranteed accuracy in the loop is 1%, and the typical accuracy is 2%, bandwidth up to 600 kHz (700mm loop perimeter) or 1MHz (300mm loop perimeter). The outer diameter typical value is 8mm, withstand voltage 10kVpk. CP9000LF is very good at the testing of low frequency large current and large power.

The advantages of CP9000LF includes: the loop that are flexible and easy plug-in can reach many places where the hard probe can’t and thus connect to subject under test; the insertion loss is almost zero, and thus has little interference on subject under test.

Standard BNC output interface, easy to connect with oscilloscope, data collector and digital voltmeter to observe the current waveform. The probe can be powered by 9V battery or external 12V DC power supply, very convenient to be used.

CP9000LF has overload alert system, and the length of the probe loop and connection cable can be customized freely to fulfill testing requirement in different situation.


Adapter CK-612
BNC Output cable CK-310/320
9V battery

 Specification

1 Electronical Parameter

Testing Condition: 23℃, 60%RH, cable under test pass through the center of probe loop center

Type

Sensitivity (mV/A)

Peak Current(A)

Max noise

(mVrms)

Low frequency bandwidth-3dB(Hz)

Phase shift (50Hz)

Peak di/dt(kA/us)

High Frequency bandwidth-3dB

X10

X1

X10

X1

X10

X1

X10

X1

300mm

700mm

CP9060LF

100

10

60

600

3

1

0.45

<0.85°

0.015

0.25

1MHz

600kHz

CP9120LF

50

5

120

1200

3

1

0.23

<0.5°

0.03

0.5

CP9300LF

20

2

300

3000

2

1

0.15

<0.35°

0.1

1.2

CP9600LF

10

1

600

6000

2

1

0.1

<0.25°

0.2

2.5

CP9121LF

5

0.5

1.2k

12k

2

1

0.08

<0.2°

0.4

5

CP9301LF

2

0.2

3k

30k

1

0.5

0.07

<0.18°

0.9

6

CP9601LF

1

0.1

6k

60k

1

0.5

0.07

<0.18°

1.8

6

2 Other Parameter

 

Typical accuracy

±1%

Max output voltage

±6Vpk

Probe loop withstand voltage value

10kVpk

Terminal load requirement

≥100kΩ

Power method

9V battery or external DC 12 V power supply (standard adaptor)

Safety compliance

EN61010-1: 2010

EMC compliance

EN61326-1:2013 EN61000-3-2:2014  EN61000-3-3:2013