深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
CP8050A(50A/50MHz Double range selection)
CP8050A(50A/50MHz Double range selection)
Bandwidth (-3dB) DC-50MHz
Rise time ≤7ns
Continuous maximum input range 50Arms
The peak current 75A
Power supply mode DC 12V/1.2A
浏览次数:566
说明书: 产品说明书
1. Features and Applications
The CP8000 series current probes are wide band width DC/AC active current probes, featuring flat bandwidth, low noise and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.
 
Adapter CK-612
BNC Output cable CK-310/320
1、Specification
 Electrical characteristics
Model CP8050A
Bandwidth
(-3dB)
DC-50MHz
(Figure 4)
Rise time ≤7ns
Continuous
maximum input
range
50Arms
(Figure 5)
Max peak current
value
75Apk
Range 7.5A 1X
50A 10X
Overload 7.5A ≥7.5A
50A ≥75A
Current transfer
ratio
7.5A 1V/A
50A 0.1V/A
measurable
current
7.5A 1mA
50A 10mA
Amplitude
accuracy (DC,45-66Hz )
7.5A ±1%±1mA
50A ±1%±10mA
Input
impedance
Reference(Figure6)
Delay
time
Probe 14ns
BNC
(1m)
5ns
Terminal load ≥100kΩ
Power supply DC 12V/1A(Standard Adaptor)
Voltage of insulated wire 300V CATI
Safety compliance EN61010-1: 2010
EMC standard EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013

                       

                                    Fig 1 CP8050A Amplitude-Frequency Curve                                     
                                    (Frequency derating)



                                      Fig 2 CP8050A Continuous maximum input rating


                                      Fig 3 CP8050A Input Impedance-frequency curve