深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
DP6150A(1500V/100MHz)
DP6150A(1500V/100MHz)

Rise Time ≤3.5ns

Accuracy ±2%


浏览次数:748
说明书: 产品说明书

1. Summary

DP6000 Series High Voltage Differential Probes are designed for the measurement of high voltage differential signal, to meet the demand for floating measurement. 

The probes have a max 200MHz bandwidth and 7000V differential voltage which can meet the majority measurement applications. 

The users can adjust the offset output voltage of the probe.

The 5MHz bandwidth limit function can remove the higher frequency noise and interference; 

The probe has sound & light alarming function which can also be turned off manually 

It can be powered by USB port, which is convenient for the customers;

The probe is standard BNC output port which can be connected to oscilloscope of any brand. 

The probes have great CMRR which is very important in many power electronics applications.

Adapter CK-605
Alligator clip CK-261
Test hook CK-284
Insulated piston probe clip CK-281
Red & Black input extension cable CK-301
BNC Output cable CK-310/320
USB power supply cable CK-315

Model

DP6070A

DP6150A

DP6350A

DP6700A

Bandwidth(-3dB

100MHz

Rise time

≤3.5ns

Accuracy

±2%

Range selection

(Attenuation rate)

10X/100X

50X/500X

100X/1000X

100X/1000X

Maximum differential voltage(DC + Peak AC)

10X

±70V

50X

±150V

100X

±350V

100X

±700V

100X

±700V

500X

±1500V

1000X

±3500V

1000X

±7000V

Common mode voltage (Vp)

(DC + Peak AC)

±700V

±1500V

±3500V

±7000V

Maximum differential mode VS frequency curve

Reference Figure 1

Figure 2

Figure 3

     Figure 4

Maximum input

voltage-to-earth (Vrms)

  450V CATII

600V CATI*

600V CATIII

1000V CATII

600V CATIII

1000V CATII

   1000V CATIII

2300V CATI*

Input impedance

Single-ended to ground

2.5MΩ

5MΩ

5MΩ

20MΩ

Between inputs

5MΩ

10MΩ

10MΩ

40MΩ

Input capacitance

Single-ended to ground

<4pF

<4pF

<4pF

<5pF

Between inputs

<2pF

<2pF

<2pF

<2.5pF

CMRR

DC

>80dB

>80dB

>80dB

>80dB

100kHz

>60dB

>60dB

>60dB

>60dB

1MHz

>50dB

>50dB

>50dB

>50dB

Noise(Vrms)

10X

<25mV

50X

<50mV  

100X

<100mV

100X

<220mV

100X

<120mV

500X

<300mV  

1000X

<600mV

1000X

<1.2V

Differential overvoltage detection level

10X

70V

50X

150V

100X

350V

100X

700V

100X

700V

500X

1500V

1000X

3500V

1000X

7000V

Propagation  time

Probe

10X 

8.7ns

50X

8.5ns

100X

8.2ns

100X

8.9ns

100X

8.1ns

500X

7.5ns

1000X

7.4ns

1000X

6.6ns

BNC Line(1m)

About 5ns

Bandwidth limit filters (5MHz)

-3dB@5MHz

Overload indicator (red light)

Yes

Overload alarm

Yes(Can shut up manually)

Automatic save

Yes

Offset setting function

Yes Set in test mode

Terminate load

≥100kΩ

Power supply

USB 5V/1A adapter

Safety standard

IEC/EN 61010-031:2015 + AMD1:2018

EMC standard

EN61326-1:2013  EN61000-3-2:2006+A1:2009+A2:2009  EN61000-3-3:2013

*CAT I per IEC/EN 61010-031/A1:2008. No Rated Measurements Category per IEC/EN 61010-031:2015 + AMD1:2018.