Model | CP8150A | ||
Bandwidth(-3dB) |
DC-12MHz ( Fig1) |
||
Rise time | ≤29ns | ||
Continuous maximum input range |
150Arms Fig2 |
||
Max peak current value |
300Apk | ||
Range | 30A | 10X | |
150A | 100X | ||
Overload | 30A | ≥30A | |
150A | ≥300A | ||
Current transfer ratio |
30A | 0.1V/A | |
150A | 0.01V/A | ||
Lowest measurable current |
30A | 5mA | |
150A | 50mA | ||
Amplitude accuracy (DC,45-66Hz ) |
30A | ±1%±10mA | |
150A | ±1%±100mA | ||
Input impedance |
Reference Fig3 | ||
Delay Time |
Probe | About 36ns | |
BNC(1m) | About 5ns | ||
Terminal Load | ≥100kΩ | ||
Power Supply | Standard Adaptor(DC 12V/1.2A) | ||
Voltage of Insulated Wire | 600V CATII 300V CATIII | ||
Safety Compliance | EN61010-1: 2010 | ||
EMC Standard | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |