| Model | CP8030B | ||
| Bandwidth(-3dB) |
DC-50MHz ( Fig.1) |
||
| Rise time | ≤7ns | ||
|
Continuous maximum input range |
30Arms Fig. 2 |
||
|
Max peak current value |
50Apk | ||
| Range | 5A | 1X | |
| 30A | 10X | ||
| Overload | 5A | ≥5A | |
| 30A | ≥50A | ||
|
Current transfer ratio |
5A | 1V/A | |
| 30A | 0.1V/A | ||
|
Lowest measurable current |
5A | 1mA | |
| 30A | 10mA | ||
|
Amplitude accuracy (DC,45-66Hz ) |
5A | ±1%±1mA | |
| 30A | ±1%±10mA | ||
|
Input impedance |
Reference Fig. 3 | ||
|
Delay Time |
Probe | About 14ns | |
| BNC(1m) | About 5ns | ||
| Terminal Load | ≥100kΩ | ||
| Power Supply | Standard Adaptor(DC 12V/1.2A) | ||
| Voltage of Insulated Wire | 300V CAT I | ||
| Safety Compliance | EN61010-1: 2010 | ||
| EMC Standard | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 | ||