1. Introduction
OPB6000 series is the latest optical isolated voltage probe with remarkably high CMRR. The CMRR of traditional differential probe decreases fast in high-frequency range, as a result, measuring the small voltage signal waveform (e.g., the driving voltage when measuring the upper MOSFET of the half-bridge circuit) under high CM interference voltage accurately become a extremely hard task. OPB6000 series applies optical isolation technologies and gains remarkably high CMRR in all working bandwidth, helping our customers to deal with these kinds of challenging measurement with low cost.
1. Electric Specification
Model | OPB6050 |
Bandwidth (-3dB) | 500MHz |
Rise time | ≤ 0.7ns |
Terminal load | 50Ω |
Output voltage range | ±0.5V |
Typical values of host noise (Vrms) | 1mV |
DC accuracy | ≤±1% |
Isolation voltage (DC+Peak AC) | ±60kV |
Host delay | 13ns |
CMRR typical values (using standard attenuators) OPB6015/OPB6035 Standard 20X attenuator OPB6050/OPB6080/ OPB6100 Standard 50X attenuator | DC-10MHz:160dB |
10MHz-100MHz:110dB | |
100MHz-300MHz:100dB | |
300MHz-500MHz:90dB | |
500MHz-800MHz:80dB | |
800MHz-1000MHz:70dB | |
Power supply method | Front end: Battery powered, with a working time of approximately 8 hours |
Rear end: USB 5V/2A | |
Auto calibration | Yes |
Optical fiber length | Around 2m |