1. Introduction
OPL6000 series is the latest POF(power on fiber) optical isolated voltage probe with remarkably high CMRR. The CMRR of traditional differential probe decreases fast in high-frequency range, as a result, measuring the small voltage signal waveform (e.g., the driving voltage when measuring the upper MOSFET of the half-bridge circuit) under high CM interference voltage accurately become a extremely hard task. OPL6000 applies optical isolation technologies and gains remarkably high CMRR in all working bandwidth, helping our customers to deal with these kinds of challenging measurement with low cost.
1. Electric Specification
Model | OPL6100 |
Bandwidth(-3dB) | 1GHz |
Rise time | ≤ 0.35ns |
Terminal load | 50Ω |
Output voltage range | ±0.5V |
Typical output voltage noise(RMS) | 1mV |
Precision | ≤±1% |
Isolated voltage(DC + Peak AC) | ±60kV |
delay Time | 13ns |
CMRR Typical Value(with standard attenuator) OPL6015/OPL6035 with standard 20X attenuator OPL6050/OPL6080/ OPL6100with standard 50X attenuator | DC-10MHz:160dB |
10MHz-100MHz:100dB | |
100MHz-300MHz:90dB | |
300MHz-500MHz:80dB | |
500MHz-800MHz:70dB | |
800MHz-1000MHz:60dB | |
Power supply | USB 5V/2A |
Auto-zero set function | Yes |