深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
HCP8300A(300A/DC~ 8 MHz)
HCP8300A(300A/DC~ 8 MHz)

Bandwidth(-3dB)  DC-8 MHz

Rise time  50ns



浏览次数:0
说明书: 产品说明书

1.Features and Applications

The HCP8000 series current probes are wide band width DC/AC active current probes, featuring high bandwidth, fast and accurate capture the current wave, accuracy up to 1% and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.


Large Pliers

Model

HCP8150(A)

HCP8300(A)

HCP8500

Bandwidth

(-3dB)

HCP8150

DC-12 MHz

(Figure 10.a)

HCP8300

DC- 6 MHz

(Figure 13.a)

DC-5MHz

(Figure 16)

HCP8150A

DC-22 MHz

(Figure 10.b)

HCP8300A

DC-8 MHz

(Figure 13.b)

Rise time

HCP8150

29ns

HCP8300

58ns

70ns

HCP8150A

16ns

HCP8300A

50ns

Continuous

maximum input

range

HCP8150

150Arms

Figure 11.a

HCP8300

300Arms

(Figure 14.a)

500Arms(Figure 17)

HCP8150A

150Arms

Figure 11.b

HCP8300A

300Arms

(Figure 14.b)

Max peak current value

300Apk

500Apk

750Apk

Range

30A

10X

50A

10X

75A

10X

150A

100X

300A

100X

500A

100X

Overload

30A

30APk

50A

50APk

75A

75APk

150A

300APk

300A

500APk

500A

750APk

Current transfer ratio

30A

0.1V/A

50A

0.1V/A

75A

0.1V/A

150A

0.01V/A

300A

0.01V/A

500A

0.01V/A

measurable

current

30A

10mA

50A

10mA

75A

10mA

150A

100mA

300A

100mA

500A

100mA

Amplitude

accuracy (DC,45-66Hz )

30A

±1%±10mA

50A

±1%±10mA

75A

±1%±10mA

150A

±1%±100mA

300A

±1%±100mA

500A

±1%±100mA

Input

impedance

HCP8150

Referenc

Figure 12.a

HCP8300

ReferenceFigure 15.a

Reference

(Figure 18)

HCP8150A

Referenc

Figure 12.b

HCP8300A

ReferenceFigure 15.b

Delay

time

Probe

HCP8150

36ns

41ns

42ns

HCP8150A

30ns

BNC

(1m)

5ns

Terminal load

≥100kΩ

Power supply

DC 12V/1AStandard Adaptor

Voltage of insulated wire

600V CATII  300V CATIII

Safety compliance

EN61010-1: 2010+A1:2019  EN 61010-2-032:2019

EMC standard

EN61326-1:2013  EN61000-3-2:2014  EN61000-3-3:2013