1.Features and Applications
The HCP8000 series current probes are wide band width DC/AC active current probes, featuring high bandwidth, fast and accurate capture the current wave, accuracy up to 1% and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.
Small Pliers
Model | HCP8030(C/D/H) | HCP8050 | HCP8070 | ||||
Bandwidth (-3dB) | HCP8030 | DC-50MHz(Figure1.a) | DC-50MHz (Figure4) | DC-30MHz (Figure7) | |||
HCP8030C | DC-70MHz(Figure1.b) | ||||||
HCP8030D | DC-100MHz(Figure1.c) | ||||||
HCP8030H | DC-120MHz(Figure1.d) | ||||||
Rise time | HCP8030 | ≤7ns | ≤7ns | ≤11.6ns | |||
HCP8030C | ≤5ns | ||||||
HCP8030D | ≤3.5ns | ||||||
HCP8030H | ≤2.92ns | ||||||
Continuous maximum input range | HCP8030 | 30Arms(Figure2.a) | 50Arms (Figure5) | 70Arms (Figure8) | |||
HCP8030C | 30Arms(Figure2.b) | ||||||
HCP8030D | 30Arms(Figure2.c) | ||||||
HCP8030H | 30Arms(Figure2.d) | ||||||
Max peak current value | 50Apk | 75Apk | 100Apk | ||||
Range | 5A | 1X | 7.5A | 1X | 10A | 2X | |
30A | 10X | 50A | 10X | 70A | 20X | ||
Overload | 5A | ≥5APk | 7.5A | ≥7.5APk | 10A | ≥10APk | |
30A | ≥50APk | 50A | ≥75APk | 70A | ≥100APk | ||
Current transfer ratio | 5A | 1V/A | 7.5A | 1V/A | 10A | 0.5V/A | |
30A | 0.1V/A | 50A | 0.1V/A | 70A | 0.05V/A | ||
measurable current | 5A | 1mA | 7.5A | 1mA | 10A | 2mA | |
30A | 10mA | 50A | 10mA | 70A | 20mA | ||
Amplitude accuracy (DC,45-66Hz ) | 5A | ±1%±1mA | 7.5A | ±1%±1mA | 10A | ±1%±2mA | |
30A | ±1%±10mA | 50A | ±1%±10mA | 70A | ±1%±20mA | ||
Input impedance | HCP8030 | Reference Figure(3.a) | Reference (Figure6) | Reference (Figure9) | |||
HCP8030C | Reference Figure(3.b) | ||||||
HCP8030D | Reference Figure(3.c) | ||||||
HCP8030H | Reference Figure(3.d) | ||||||
Delay time | Probe | 14ns | 14ns | 23ns | |||
BNC (1m) | 5ns | ||||||
Terminal load | ≥100kΩ | ||||||
Power supply | DC 12V/1A(Standard Adaptor) | ||||||
Voltage of insulated wire | 300V CAT I | ||||||
Safety compliance | EN61010-1: 2010+A1:2019 EN 61010-2-032:2019 | ||||||
EMC standard | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |