深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
CTA400( 400A/500kHz)
CTA400( 400A/500kHz)

Primary nominal continuous Direct current  (IPN DC)  400A

Bandwidth(±3dB)   500kHz



浏览次数:0
说明书: 产品说明书

1. Summary

CTA series is the ultra-accuracy transducer that can measure both DC and AC. Its current range covers from 60A to 2000A with precision of 0.03% and 800 kHz bandwidth. By using Flux-gate technic, the CTA series realized high accurate measurement, excellent linearity, low DC offset, lower temperature drift, low insertion loss, high immunity to external field and low noise.

 

CTA series transducer includes CTA60(60A),CTA200(200A),CTA400(400A),CTA700(700A)  CTA1000(1000A) and CTA20002000A. CTA60 ,CTA200,CTA400 have measurement aperture of 26mm; CTA700,CTA1000 have measurement aperture of 30mm and CTA2000 have measurement aperture of 70mm. CTA series transducers have standard 9 pin D-Sub male interface and LED Indicator, making the system not only easy to use but also reliable.



1. Specification

Test temperature: 25; Voltage Supplied: ±Uc =±15V

Type

CTA400

Primary nominal continuous

Direct current  (IPN DC)

400A

Primary nominal rms current (IPN)

282A

Primary current, measuring range

(IPM)

±400A

Conversion ratio KN

1:2000

Secondary current (IS)

±200mA

Accuracy (DC,50/60Hz sine wave)

≤±(0.03% of the readings +30uA)

Bandwidth(±3dB)

500kHz

Measuring resistance over

operating current temperature and

supply voltage range

RM min

RM max

0

2.5Ω

FIG.3

Overload capability @ pulse of

100ms

±2000A

Supply voltage

±15V(±5%)

Supply current

80mA+IS

Rated operational

voltage  

RMSIEC61010-1

Basic insulation

2000V

Reinforced insulation

600V

Max measurement aperture

26mm

Second interface

D-Sub-9Pin

Fastening screws and tightening

torque

M4 steel screw *42.8Nm

M5 steel screw *23.7Nm

图片2.png

                           Figure 3  CTA400 Maximum measuring resistor versus primary current